Product Description
10KVA to 20KVA True On Line UPS
Key Features:
- True double-conversion
- Microprocessor control optimizes reliability
- Output power factor 0.8 / 0.9
- Wide input voltage range
- Cold start function
- Emergency power off function (EPO)
- Generator compatible,
- User friendly digital LCD display
- SNMP+USB+RS-232 multiple communications
- 3-stage extendable charging design for optimized
battery performance - Advanced battery management
Technical Specification Of 10KVA to 20KVA True On Line UPS:
MODEL | BPSLF10 | BPSLF15 | BPSLF20 | |
CAPACITY | 10KVA/8000W | 15KVA/12000W | 20KVA/16000W | |
INVERTER TYPE | IGBT Based DSP Technology | |||
INPUT | Voltage Range | 400V/415V/440V AC ±20%, (3Ph+N+PE) | ||
Frequency | 46Hz-54Hz | |||
Power Factor | ≥0.98 | |||
OUTPUT | Voltage | 230V AC,Single Phase | ||
Voltage Regulation | ±1% | |||
Load Regulation | ±2% | |||
Frequency | 50Hz ± 0.2Hz | |||
Power Factor | 0.8 Standard / 0.9 Optional | |||
Waveform | Pure Sine Wave | |||
Total Harmonic Distortion | < 3% Linear load, < 5% non linear load | |||
Crest Factor | 3∶1 | |||
Overload Capability | 10 Minutes at 110% load, 5 Minutes at 120% | |||
Efficiency(on line mode) | >90% | |||
BATTERY | DC Voltage | 192 VDC /216 VDC / 240 VDC /360 VDC | ||
Recharge Current | Adjustable | Adjustable | Adjustable | |
Transfer Time | 0ms (AC mode→Battery mode) | |||
Noise Level (1m) | <45dB | |||
Ambient Temperature | 0~45℃ | |||
Duty Cycle | Continuous | |||
Cooling | Forced air cooling | |||
Bypass Switch | Static bypass switch / Manual bypass Switch (Optional) | |||
Humidity | 0~95% (Non-condensing) | |||
Sea Level Elevation | <1500m | |||
Metering | LCD Display input/output Voltage, Frequency, Battery voltag, Battery capacity, Loading rate. | |||
Protections | Input, Output – Low and High , Battery low and high voltage, Input, output – MCB, Transient Surge,Battery – MCB/Fuse, Short circuit, Over load,Temperature | |||
Trip Conditions | Over load, Over and Under voltage, Short Circuit,low battery,Over Temperature | |||
Indications | Mains ON, Inverter ON, Battery Low, Overload. | |||
Isolation Transformer |
Internally / Externally ( Optional) | |||
Alarms | Audio for extreme battery low voltage / Mains fail | |||
Communication | Smart RS232, SNMP(Optional),USB (Optional) | |||
Emergency Switch OFF | Emergency Switch OFF Avilable ( Optional) | |||
*Specification and ups image are subject to change without notice due to constant improvement in design & technology. |